Page 58 - {COVP2017}
P. 58

Code of Veterinary Practice For Poultry Processing Plant

                      Where an automatic chlorinator is used, regular monitoring should
                      be carried out to ensure accuracy of quantity added.
                9.6   Benches, trays tables or chutes receiving poultry carcasses from
                      spin chillers should be self-draining.
                9.7   Where ice is added to continuous spin chillers, it may be accepted
                      as portion of the minimum requirement of 0.75 litres of water per
                      poultry carcass.
                9.8   Ice used in poultry processing whether manufactured ice or ice
                      made on the premises should be made from potable water and
                      should be stored and handled to ensure that it is protected from
                      contamination at all times. Personnel should not enter a crushed
                      ice storage freezer where ice is augered from the floor unless the
                      ice has been protected from contamination.
                9.9   Non agitated immersion chill tanks may be accepted where a water
                      supply is limited, provided the maximum temperature of the water
                      in the tank does not exceed 4ºC and is maintained in a reasonably
                      clean condition.

                9.10  Motors and drive gears located directly over spin wash and spin
                      chill tanks should be provided with protective trays to prevent
                      contamination of the product.

           10. 0  DRIP LINES AND DRAINING
                10.1  Overhead drip lines should be positioned to avoid contamination
                      of dressed poultry carcasses by drip or contact.
                10.2  Drain trays or troughs should be placed under overhead drip lines
                      where they pass over a passageway or section where dressed
                      poultry carcasses are being processed. Drainage from the tray or
                      trough should be directed to a waste or drain.
                      The line should be positioned to ensure that suspended poultry
                      carcasses will not contact plant personnel. The speed of the drip
                      line should ensure that suspended poultry carcasses adequately
                      drain.
                10.3  The number of draining racks or draining facilities should
                      commensurate with daily throughput of the premises.