Code of Veterinary Practice For Poultry Processing Plant 36 11.3 Basic Construction Construction requirements should be in accordance with the sections headed “Basic Construction” and “Facilities” 11.4 Speci c Construction Requirements 11.4.1 Separate rooms should be provided for the following operations: - boning, cutting and trimming poultry - curing - smoking/curing 11.4.2 The minimum distance from the oor to a wall or ceiling plate in the cooking room should be 3m. 11.5 Poultry Meat Preparation Room 11.5.1 Where poultry meat is to be prepared by boning, slicing, mincing or the like, a separate room should be provided. 11.5.2 The meat preparation room should be constructed in accordance with the section “Basic Construction” except that where meat is held so as not to rise above 7oC. The room need not be temperature controlled. 11.6 Brining and Pickling Rooms 11.6.1 Where brining or pickling operations are carried out, a separate room, capable of being temperature controlled at or below 10 degrees Celsius, should be provided. 11.6.2 Pickling tubs should be of sanitary construction and of approved design. 11.7 Poultry Meat Thawing Rooms 11.7.1 Where thawing is by immersion in water, the rate of change of water should ensure that the mass of water exchanged in a unit of time is at least equal to the mass of meat treated in the same time. 11.7.2 Thawing should be constructed in accordance with the section headed “Chillers”.