Code of Veterinary Practice For Poultry Processing Plant

                b)    Processing Waste Drainage
                      2.10.5   The drainage system from processing areas should be
                              designed to enable rapid removal of wash down or other
                              water from the floors of departments. The system should
                              ensure effective and expeditious removal of plant effluent
                              from premises.

                      2.10.6   Drainage waste outlets should be provided to adequately
                              remove waste in processing areas.
                      2.10.7   Each drainage waste should be at least 100mm in
                              diameter and be fitted with perforated or grilled drain
                              covers.

                      2.10.8   Drains should be equipped with effective, P, U or S shaped
                              deep seal traps and be adequately vented to the outside
                              atmosphere.
                      2.10.9   Floors should be evenly graded to the trapped drainage
                              wastes.

                      2.10.10  Drainage for the removal of viscera, feathers etc. within
                              the packing, dressing and killing areas should take the
                              form of a box channel drain.
                      2.10.11  Box channel should be wide enough to enable cleaning
                              and internal corners should be effectively coved.

                      2.10.12  Floor drainage valleys should be provided with approved
                              covers where necessary over walkways and the direction
                              of flow of the drains must be from clean areas to dirty
                              areas.
                      2.10.13  Where viscera, feathers and other wastes are removed
                              from the processing premises to the save-all by means
                              of a large diameter pipe, both ends of the pipe should
                              be made rodent proof when not in use.
                      2.10.14  Pits and tanks into which blood is received must be
                              located outside the bleeding area.
                      2.10.15  Blood pits and tanks should be constructed so that they
                              are impervious to moisture and suitably drained. They
                              should be provided with facilities to enable effective
                              cleaning.