Part 1 | Minimum Standards of Construction of Poultry Processing Premises

                      b)  shower rooms, wash basins, and sanitary conveniences;
                      c)  cleaning utensils, appliances and equipment;
                      d)  cleaning and flushing the premises, including the settling pit,
                         drains, holding and reception area and roadways;
                      e)  equipment used for cleaning live bird crates;
                      f)  cleaning vehicles used for the conveying of poultry meat from
                         the premises; and
                      g)  cleaning vehicles used for conveying birds to the premises.

                2.4   Potable Water

                      2.4.1   Potable water should be clean and free from contamination,
                              objectionable taste and odour, and shall comply with the
                              standard as specified in Food Hygiene Regulations 1985.
                      2.4.2   Where premises have in-plant chlorination facilities
                              installed, storage facilities or other means should be
                              provided to ensure a contact period of at least 20 minutes
                              between chlorination and use within the premises. The
                              chlorinated water shall have a free residual chlorine level
                              of not less than 0.25 ppm at the point of entry to the
                              premises.
                      2.4.3   In-plant chlorinators, where installed, should be of an
                              automatic, continuous type and fitted with alarms to
                              indicate failure of the apparatus.

                2.5   Potable Water Reticulation
                      2.5.1   A building on a premises should be constructed
                              so that each room except a room used for chilling
                              accommodation, is provided with an ample supply of
                              hot and cold water, delivered to water connections.
                      2.5.2   The reticulation system should be designed and installed
                              so that back siphoning of used or polluted water cannot
                              occur.

                      2.5.3   Potable water supply outlets to immersion tanks should
                              be located so that there is a disconnection between the
                              outlet and the highest point of the water in the tanks.