Part 1 | Minimum Standards of Construction of Poultry Processing Premises

                      3.10.11  The facilities, support areas and external environment
                              must be kept clean and tidy. The external environment
                              must be checked regularly for evidence of pest activity.
                              It must be kept free of food sources and breeding sites
                              (e.g. long grass, bird’s nest, food waste).

                      3.10.12  Dogs, cats and other mammalian pests must be
                              prevented from accessing the premises.

                      3.10.13  Compliance with control measures implemented by the
                              programme must be monitored regularly. Monitoring must
                              include checks for the presence or evidence of pests and
                              regular checks on pest control equipment as relevant.

                      3.10.14  The frequency of monitoring must be determined relative
                              to the type of equipment used and the amount of pest
                              activity present. Appropriate corrective actions must be
                              implemented where pests or evidence of pest activity is
                              noted.

                3.11  Ventilation
                      3.11.1   Ventilation may be provided by natural or mechanical
                              means. Mechanical ventilation should achieve at least 4
                              air changes an hour.

                      3.11.2   With mechanical ventilation systems, air intakes should
                              be properly located to avoid the intake of potentially
                              contaminated air.
                      3.11.3   Ventilation equipment of all types should be located so
                              that air from inedible product areas cannot be introduced
                              into the ventilation system.

                      3.11.4   Where roof mounted air conditioners, evaporative coolers
                              and the like are located near production lines, edible
                              product should not be contaminated with condensate
                              or overflow water.

                      3.11.5   Where mechanical ventilation system are installed to
                              help exclude dust from buildings, the system is not to be
                              regarded as a substitute for adequate insect proofing.