Code of Veterinary Practice For Poultry Processing Plant

                5.9   Evisceration Area
                      Should be separated from the washing and packaging area by walls
                      not less than 3 meters from floor to ceiling or wall plate except for
                      openings adequate for personnel and for the passage of poultry
                      carcasses.

                5.10  Refrigerated Storage
                      The premises should contain a room or rooms adequately
                      constructed and equipped for keeping under refrigeration all killed
                      poultry likely to be on the premises at any one time.

                5.11  Spin Chillers or Air Chillers
                      Where in-line chilling facilities are incorporated in the processing
                      line, they should comply with the following:
                      a)  In two-tank systems, water should not flow from the initial tank
                         to the final tank;
                      b)  Overflow drains should be connected direct to the drainage
                         system;
                      c)  The rate of change of water should approximate 0.75 litres per
                         poultry carcass. Details of the method of chlorination and the
                         resultant free residual chlorine levels should be stated in the
                         specifications accompanying the plans.
                      d)  Where air chilling facilities are used, the air chill room temperature
                         should be maintained at 4°C or lower.

                5.12  Hand Wash Facilities
                      Hand wash facilities should be provided at the recommended ratio
                      of one hand basin per 10 employees and be sited at all doors and
                      major work station. The facility shall be hands-free.

                5.13  Sterilisers
                      An adequate number of steriliser units should be provided. Approved
                      chemical sterilisers would be acceptable.