Page 29 - {COVP2017}
P. 29

Part 1 | Minimum Standards of Construction of Poultry Processing Premises

                              the killing operation. A voltmeter to indicate the voltage
                              being used should be fitted to the equipment.

                5.7   Bleeding Area
                      5.7.1   The bleeding area should be separated from the shackling
                              area by walls of a height not less than 3 meters from floor
                              to ceiling or wall plate except for self-closing doors for
                              personnel and openings adequate for the passage of
                              poultry carcasses.

                      5.7.2   The bleeding operation should be separated from the
                              scald area by a wall or partition to at least shackle
                              conveyor height.
                      5.7.3   Blood from the bleeding area should be removed via a
                              blood drain or by a continuous automatic method.
                      5.7.4   Where bleeding is carried out with automatic equipment,
                              the method should be stated and be humane in operation.
                      5.7.5   Hand wash and sterilising facilities should be available in
                              the immediate vicinity of the bleeding area, whether this
                              operation is performed manually or not.

                5.8   Scalding and Defeathering Area
                      5.8.1   This area should be separated from the evisceration
                              area by full height walls except for openings adequate
                              for personnel and the passageway of poultry carcasses.
                      5.8.2   Adequate facilities should be provided in the scald and
                              defeathering area for the removal of steam to the outside
                              atmosphere.
                      5.8.3   Scalding equipment should be designed and constructed
                              so that the potable water line cannot be contaminated
                              and so that there is a continuous flow of potable water
                              into the scald. The overflow from the scald should be
                              large enough to allow feathers and water to be freely