Part 1 | Minimum Standards of Construction of Poultry Processing Premises

                5.14  Carton and Wrapping Materials Storage

                      5.14.1   The storage and dispensing facilities provided in the
                              processing room should be adequate and capable of
                              keeping wrapping materials above floor.

                      5.14.2   A store room for holding cartons, and packing and
                              wrapping materials intended for use in connection with
                              edible production should be provided. It should be
                              separated from all other storage facilities and should be
                              constructed so that it is insect, vermin and dust proof
                              and provided with racks not less than 300 mm above the
                              floor on which materials may be stored. Cartons may be
                              stored away from walls on pallets.

                5.15  Inedible Material
                      5.15.1   Poultry waste should be stored, pending its removal from
                              the premises, in leak proof containers with close fitting
                              covers located outside the premises, under cover, on a
                              concrete slab that is curbed and drained.
                      5.15.2   Poultry waste containers shall be leak proof, capable
                              of being effectively cleaned and distinguishable from
                              containers from edible product by being coloured red or
                              marked with a red band not less than 100 mm in width
                              around the outer circumference of the top of the container.
                      5.15.3   Buildings intended for rendering purposes to produce or
                              store inedible tallow, meat meal and fertiliser should be
                              constructed in a manner to facilitate the maintenance of
                              hygienic condition. They should be completely separated
                              from edible departments except for a minimum opening
                              for passage of inedible material. Such a passage must
                              slope away from the processing area.
                      5.15.4   Where treatment of by-products is to be other than by
                              dry-rendering, the building should be located not less
                              than 30m from any building in which birds are slaughtered
                              or dressed or in which poultry meat is treated or stored.

                      5.15.5   The walls of the rendering department should not be less
                              than 3.6m high from floor to ceiling or wall-plate.